Falcon Technologies KSA
FRP / GRP Tanks — Falcon Technologies
HomeFRP / GRP Tanks

Tank Solutions

FRP / GRP Tanks

Fiberglass tanks engineered for water, wastewater, chemicals and diesel — built to your site, not a catalogue size.

Tank Solutions

FRP / GRP Tank Manufacturer for Saudi Arabia and the GCC

Fiberglass-reinforced plastic (FRP), also called GRP, resists corrosion, is light for its strength and stands up to the heat and humidity of Saudi Arabian sites. Falcon designs and fabricates FRP/GRP tanks around the stored liquid, concentration, temperature and installation location rather than starting from a fixed size chart.

From potable water and process water to wastewater, chemicals and diesel, each tank is built with a resin and laminate system matched to the service, then inspected and documented before it leaves the factory.

FRP / GRP Tanks by Falcon Technologies in Saudi Arabia
Tank Solutions

What We Offer

Corrosion-resistant construction

Glass-reinforced laminate that does not rust and handles aggressive liquids when the resin is chosen correctly.

Resin matched to service

Resin and laminate selected for the stored liquid, concentration and operating temperature.

Custom sizes and shapes

Cylindrical, rectangular and special-purpose tanks sized to your footprint and access.

Engineered fittings

Nozzle orientation, manholes, supports and lifting points set out on approved drawings.

Controlled manufacturing

Material control, layer construction, thickness and reinforcement checked at defined inspection points.

Restoration support

If an FRP tank is ever damaged, Falcon can restore and reinforce it rather than replace it.

Technical Snapshot

Construction
Hand lay-up, filament winding and project-specific fabrication
Stored liquids
Potable water, process water, wastewater, chemicals, diesel and industrial liquids
Orientation
Vertical, horizontal, underground and aboveground
Shapes
Cylindrical, rectangular and custom tanks
Fittings
Nozzles, manholes, supports, anchoring and lifting arrangements per drawing
Documentation
GA / shop drawings, inspection records and material traceability

Where It’s Used

Water & wastewater plantsOil & gas facilitiesPetrochemical & chemical plantsPower & utilitiesManufacturing plantsConstruction & infrastructure

From Enquiry to Handover

  1. 01

    Review the application

    Stored liquid, concentration, temperature, capacity and installation location.

  2. 02

    Select resin and laminate

    Construction chosen for the service, with drawings issued for approval.

  3. 03

    Fabricate and inspect

    Hand lay-up or filament winding with in-process and final inspection.

  4. 04

    Test and hand over

    Leak or hydrostatic and dimensional checks as applicable, then documented handover.

Reference Sizes

Documented configurations we can reference as a starting point — confirmed per project, not a committed availability.

Underground diesel (FRP)
20,000 L — Ø2,500 mm × 4,350 mm long; 30,000 L — Ø2,500 mm × 6,400 mm long.
Aboveground horizontal (FRP)
100,000 L reference — Ø3.50 m × 11 m long × 4.00 m high.

Indicative reference configurations from prior project and design context — not a committed catalogue range or current availability. Final capacity and dimensions are confirmed against the approved drawing and QA file for each project.

Standards & Compliance

ASTM D3299-26
Filament-wound FRP corrosion-resistant tanks, within its scope and design conditions.
ASTM D4097-19
Contact-molded FRP tanks; the 2019 edition is marked withdrawn by ASTM in 2026 — confirm the current project-approved basis.
AWWA D120-19(R25)
Thermosetting FRP tanks for water service — confirm purchaser requirements and exact scope.
AWWA D121-24
Bolted aboveground FRP panel-type tanks for water storage (not a blanket FRP standard).

A standard reference is not proof of third-party certification. Falcon states “designed and manufactured to” a standard only when it is backed by the controlled design and QA file; chemical, potable-water and underground suitability require separate product-specific evidence. Saudi/GCC approvals (SASO/SABER, Civil Defense, environmental, municipal, utility and owner approvals) are project- and product-specific.

Accessories & Fittings

Access / manwayInlet / outletOverflowVentDrainLevel gauge / transmitterLadder, platform & handrailsLifting lugsHold-downs / anchorsBafflesSample pointInstrument portsPump / filter / skidLeak monitoringGrounding / instrumentationInterstitial monitoring (double-wall)

Nozzle size, material, reinforcement and orientation are set in the nozzle schedule for each tank. Accessories are fitted as the service requires.

Frequently Asked Questions

What is the difference between FRP and GRP tanks?

They describe the same family of material — a resin laminate reinforced with glass fiber. FRP (fiber-reinforced plastic) and GRP (glass-reinforced plastic) are used interchangeably.

Can FRP tanks store chemicals?

Yes. FRP is widely used for chemical storage because the resin system can be selected for the specific chemical, concentration and temperature. Share those details and our engineers confirm the suitable construction before fabrication.

Can an FRP tank be installed underground?

Yes. Underground FRP tanks are supported by foundation, anchoring and installation details in the design package, with the design accounting for soil and external loads.

Falcon Technologies industrial tank and service facility
Let's Work Together

Ready to Start Your Next Project?

Get in touch with our engineering team for a free consultation and a tailored proposal for your site.